< Back
other-ringversuch

2017 - nanoanalytics - Quantitative X-ray microanalysis by SEM/EDX

Organizer
NanoAnalytics, Münster
Material
Laboratory Comparison EDX (LV) - Laboratory Comparison of nanoanalytics, Münster for quantitative X-ray microanalysis using SEM/EDX acc. to ISO 22309 on a chromium-nickel steel
Literature
Report on Laboratory Comparison EDX (LV17)
Download

Major elements [wt %]

CRB
RV
1sRV
Z-Score
Fe
52.700
52.400
1.000
0.300
Cr
20.000
20.600
0.700
-0.900
Ni
16.800
15.900
0.500
1.800
Mn
7.100
7.540
0.400
Mo
2.800
2.790
0.400
Si
0.330
0.450
0.100
V
0.130
0.190
0.100
Cu
0.050
0.260
0.100
Co
0.300
0.100

Legende

CRB
Interlaboratory test
1s-RV
Z-score
*
CRB Results
Interlaboratory Test Results
Standard Deviation Interlaboratory Test
Difference between the measured value and the average value of the interlaboratory test
Value not certified